Malfunctioning ‘motor controller’ caused fire in BRT buses: report

Published October 15, 2020
— Photo courtesy Abdul Majeed Goraya/File
— Photo courtesy Abdul Majeed Goraya/File

PESHAWAR: The recent fire incidents in the Peshawar Bus Rapid Transit buses were caused by the malfunctioning of a motor controller installed between hybrid batteries and electrical motors, reveals a month long inspection of the vehicles.

The BRT service formally launched on Aug 13 has been suspended since Sept 16 after fire broke out in four buses.

A 20-member team of the Chinese bus maker, Xiamen Golden Dragon, had come to Peshawar last month to detect the cause of fire.

In a report submitted to the TransPeshawar, the operator of bus service, the company has noted that the motor control unit (MCU) acted as the core of the hybrid systems in buses and it was managed by a programme developed according to input of external conditions.

Manufacturer plans to redesign those controllers, install temperature sensors

It said normally, the ripple current generated by the DC-AC conversion of current flows was either absorbed by batteries or smoothed via capacitors in motor controller.

The company, however, said the failure of capacitors to perform that task led to the short-circuiting of high-volt power circuit and eruption of fires in buses.

It said the peak current was supposed to be restrained by software update to limit the flow of the current from the motor controller change but certain electronic components in bus MCUs were damaged by the abnormal current before the software update and therefore, accidents occurred.

The company said it would address the issue by redesigning and replacing bus motor controllers.

It also said the insulated gate bipolar transistor in the motor controller would be changed to reserve larger power capacity and improve the performance of the temperature resistance and the current conversion efficiency.

In the report, the company said temperature sensors would be installed in motor controllers to record and issue warning for any abnormal temperature in the unit. It said for 12 meters long buses, single motor controller would be changed to dual one.

An audit by the Auditor General of Pakistan last year had found out that the delivery of 51 buses more than a year before the completion of civil works due to political consideration caused depreciation of hybrid batteries and led to losses of Rs5 million until June 2019.

The AGP said any further delay in the resumption of operation would further increase the loss due to the depreciation of batteries.

Published in Dawn, October 15th, 2020

Opinion

Editorial

Digital growth
Updated 25 Apr, 2024

Digital growth

Democratising digital development will catalyse a rapid, if not immediate, improvement in human development indicators for the underserved segments of the Pakistani citizenry.
Nikah rights
25 Apr, 2024

Nikah rights

THE Supreme Court recently delivered a judgement championing the rights of women within a marriage. The ruling...
Campus crackdowns
25 Apr, 2024

Campus crackdowns

WHILE most Western governments have either been gladly facilitating Israel’s genocidal war in Gaza, or meekly...
Ties with Tehran
Updated 24 Apr, 2024

Ties with Tehran

Tomorrow, if ties between Washington and Beijing nosedive, and the US asks Pakistan to reconsider CPEC, will we comply?
Working together
24 Apr, 2024

Working together

PAKISTAN’S democracy seems adrift, and no one understands this better than our politicians. The system has gone...
Farmers’ anxiety
24 Apr, 2024

Farmers’ anxiety

WHEAT prices in Punjab have plummeted far below the minimum support price owing to a bumper harvest, reckless...